BARCODE SCANNERS · HAZARDOUS AREAS · BARTEC

Bartec hazardous-area scanners: BCS36xx ex and SC9

Barcode scanners and a smart scanner for hazardous areas. The Bartec BCS36xx ex handheld scanners are available for Zone 1/21 (IS) and Zone 2/22 (NI), each corded or with Bluetooth. The Android smart scanner SC9 is approved for Zone 1 and combines a Zebra scan engine with 5G and Wi-Fi 6.
AT A GLANCE

Key facts

Bartec BCS36xx ex
Current modelsBartecATEX · IECEx
Zone 1/21IS variant, ATEX and IECEx
Zone 2/22NI variant
100,000+scans per charge (BCS3678ex-IS)
IP65BCS36xx ex
12.2 mreading distance SC9 (Zebra SE55)

In chemical and pharmaceutical production, refineries, tank farms or paint shops, only devices approved for the respective zone may be used. The BCS36xx ex follow the form factor and dimensions of the Zebra DS3600 series and use a Zebra scan engine. Which zone applies is determined by your risk assessment; we help you choose the right device.

Well suited for
  • Zone 1 and 21: BCS3608ex-IS, BCS3678ex-IS, SC9
  • Zone 2 and 22: BCS3608ex-NI, BCS3678ex-NI
  • North America: Class I, II, III Division 1 or 2
  • Mobile applications with app, camera and 5G in Zone 1 (SC9)
Less suited for
  • Areas without explosion protection requirements: Zebra DS3678 or Granit Ultra
  • Battery swapping and charging inside the hazardous area (SC9: only outside, according to the manufacturer)
SPECIFICATIONS

Detailed specifications

Bartec BCS36xx ex

IS (Zone 1/21)NI (Zone 2/22)
ApprovalZone 1/21 and Class I, II, III Division 1Zone 2/22 and Class I, II, III Division 2
ATEX marking (BCS3678ex-IS)II 1G Ex ia ma op is IIC T4 Ga
II 1D Ex ia ma op is IIIC T135 °C Da IP64
per certificate
ModelsBCS3608ex-IS (corded), BCS3678ex-IS (Bluetooth)BCS3608ex-NI (corded), BCS3678ex-NI (Bluetooth)
Scan engineZebra SE4750-HP, 1D and 2D omnidirectional; up to 20 codes at onceZebra SE4750 (standard range HP) or SE4850 (extended range)
InterfacesUSB-SPP (virtual COM port), RS-232 via supply modulesUSB-SPP, RS-232, RS-422, RS-485
SealingIP65IP65
Operating temperature-20 °C to 50 °Cnot specified
Batteryover 100,000 scans per charge (BCS3678ex-IS)not specified
Weight491 g (BCS3678ex-IS)309 g with SE4750, 334 g with SE4850
Dimensions185 × 76 × 142 mm185 × 76 × 142 mm
ConfigurationZebra 123Scan via USBZebra 123Scan via USB

Bartec SC9 Smartscanner

ApprovalZone 1 and Division 1; ATEX, IECEx, NEC/CEC
Operating system and processorAndroid 13, upgradeable to Android 15; Qualcomm QCM6490, 8 cores, 2.7 GHz
Memory8 GB RAM, 128 GB
Display6.1 inch AMOLED, 1,080 × 2,340 pixels, Gorilla Glass Victus, operable with gloves and stylus
Scan engineZebra SE55 with IntelliFocus, 1D and 2D up to 12.2 m
Wireless5G, LTE, dual SIM (nano SIM and eSIM), Wi-Fi 6, Bluetooth 5.2
Camera48 MP rear, 8 MP front
Battery4,300 mAh; swapping and charging only outside the hazardous area
RuggednessIP68, tested to MIL-STD-810H
Operating temperature-20 °C to 55 °C
Weight and size370 g; 168.7 × 83.4 × 30.8 mm

Source: manufacturer data sheets and product pages, as of October 2026. Subject to change; individual variants may differ. Prices and delivery times are available in the shop.

VARIANTS

Variants and accessories

DeviceZoneVersionShop
BCS36xx ex ISZone 1/21, Div 1corded or Bluetoothin the shop
BCS36xx ex NIZone 2/22, Div 2corded or Bluetooth; standard range HP or extended rangein the shop
SC9Zone 1, Div 1Android smart scanner with 5Gin the shop

Accessories per zone: batteries, 4-slot chargers, base stations and supply modules for 24 V DC, 110 to 120 V AC and 230 V AC. Where charging and battery swapping are permitted is defined in the operating manual.

COMPARISON

Zone 1, Zone 2 or standard device?

BCS3678ex-ISBCS3678ex-NIZebra DS3678
Ex approvalZone 1/21Zone 2/22none
Weight (Bluetooth)491 g309 to 334 g407 g (SR)
SealingIP65IP65IP65, IP68
Operating temperature-20 °C to 50 °Cnot specified-20 °C to 50 °C
Dimensions185 × 76 × 142 mm185 × 76 × 142 mm18.5 × 7.6 × 14.2 cm

Devices for Zone 1 may generally also be used in Zone 2, but not the other way round. If only Zone 2 is required, the NI variant is lighter. Without explosion protection requirements, a standard device such as the Zebra DS3678 is sufficient. The device marking and your risk assessment are decisive.

FAQ

Frequently asked questions

What is the difference between Zone 1 and Zone 2?

In Zone 1 an explosive gas atmosphere is likely to occur occasionally in normal operation, in Zone 2 it is not likely or only for a short time. Zones 21 and 22 are the equivalent zones for combustible dust. The operator defines the zoning in its risk assessment.

May I use a Zone 1 device in Zone 2?

Yes, devices for Zone 1 are generally also suitable for Zone 2, but not vice versa. The device marking and the requirements of your risk assessment are decisive.

How is the BCS36xx ex connected?

Via supply modules with USB (virtual COM port) or RS-232, with RS-422 and RS-485 additionally available for the NI variant. Configuration is done with the Zebra 123Scan utility via USB.

Can I swap the battery in the hazardous area?

Not for the SC9 according to the manufacturer: swapping and charging only outside the hazardous area. For the BCS scanners, the requirements of the respective operating manual apply.

DOWNLOADS

Data sheets and manufacturer information

Bartec provides certificates, operating manuals and data sheets on the product pages.

Not sure which scanner fits?